Modifying Kinect placement to improve upper limb joint angle measurement accuracy
- Author(s)
- Seo, Na Jin; 허필원; Fathi, Mojtaba R.; Crocher, Vincent
- Type
- Article
- Citation
- Journal of Hand Therapy, v.29, no.4, pp.465 - 473
- Issued Date
- 2016-10
- Abstract
- Study Design Repeated measures. Introduction The Kinect (Microsoft, Redmond, WA) is widely used for telerehabilitation applications including rehabilitation games and assessment. Purpose of the Study To determine effects of the Kinect location relative to a person on measurement accuracy of upper limb joint angles. Methods Kinect error was computed as difference in the upper limb joint range of motion (ROM) during target reaching motion, from the Kinect vs 3D Investigator Motion Capture System (NDI, Waterloo, Ontario, Canada), and compared across 9 Kinect locations. Results The ROM error was the least when the Kinect was elevated 45° in front of the subject, tilted toward the subject. This error was 54% less than the conventional location in front of a person without elevation and tilting. The ROM error was the largest when the Kinect was located 60° contralateral to the moving arm, at the shoulder height, facing the subject. The ROM error was the least for the shoulder elevation and largest for the wrist angle. Discussion Accuracy of the Kinect sensor for detecting upper limb joint ROM depends on its location relative to a person. Conclusion This information facilitates implementation of Kinect-based upper limb rehabilitation applications with adequate accuracy. Level of Evidence 3b © 2016 Hanley & Belfus
- Publisher
- Hanley and Belfus, Inc.
- ISSN
- 0894-1130
- DOI
- 10.1016/j.jht.2016.06.010
- URI
- https://scholar.gist.ac.kr/handle/local/31613
- 공개 및 라이선스
-
- 파일 목록
-
Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.