레이저침에 활용되는 830 nm, 905 nm 레이저의 안전성 연구

Metadata Downloads
Abstract
Objectives : As the attempts to make good uses of laser acupuncture in korean medicine have been steadily carried on, to ensure the safety is needed to increase the use of laser acupuncture. The aim of this study was to examine the safety of using laser acupuncture therapy irradiated with 830 nm laser and 905 nm laser.
Methods : Fifteen rats were randomly divided into three experimental groups - Intact ; no therapy group. LAT830 ; laser acupuncture therapy(830 nm) group at GB34·GB39. LAT905 ; laser acupuncture therapy(905 nm) group at GB34·GB39. During eight weeks of treatment, LAT830, LAT905 were treated 2 times weekly, frequency 20 Hz, intensity 20 mW. Test items were mortality, body weight, food consumptions, hematological values, blood chemical values, urinalysis values, absolute organ weights and relative organ weights.
Results : Statistically significant differences were not found among 3 groups. The values measured in LAT830, LAT905 and Intact(no therapy) group have shown similar results and it indicated that LAT830, LAT905 had no abnormal influence on the reaction of living bodies. There was little difference on the liver weight of relative organ weight test between laser-treated groups(LAT830, LAT905) and Intact group.
Conclusions : In conclusion, laser acupuncture therapies irradiated with 830 nm laser and 905 nm laser caused no abnormal reaction of living bodies. More studies are needed to further establish the safety of many other laser acupuncture therapies.
Author(s)
유평식김영선문영민정성호윤대환최찬헌나창수이석희
Issued Date
2012-09
Type
Article
URI
https://scholar.gist.ac.kr/handle/local/15838
Publisher
경락경혈학회
Citation
Korean Journal of Acupuncture, v.29, no.3, pp.441 - 452
ISSN
2287-3368
Appears in Collections:
Department of Mechanical and Robotics Engineering > 1. Journal Articles
공개 및 라이선스
  • 공개 구분공개
파일 목록
  • 관련 파일이 존재하지 않습니다.

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.