OAK

Microfluidic cell concentrator with a reduced-deviation-flow herringbone structure

Metadata Downloads
Author(s)
Hyun, Ji-chulChoi, JongchanJung, Yu-gyungYang, Sung
Type
Article
Citation
Biomicrofluidics, v.11, no.5
Issued Date
2017-09
Abstract
In this study, a microfluidic cell concentrator with a reduced-deviation-flow herringbone structure is proposed. The reduced-deviation-flow herringbone structure reduces the magnitude of deviation flow by a factor of 3.3 compared to the original herringbone structure. This structure shows higher recovery efficiency compared to the original herringbone structure for various particle sizes at high flow rate conditions. Using the reduced-deviation-flow herringbone structure, the experimental results show a recovery efficiency of 98.5% and a concentration factor of 3.4x at a flow rate of 100 ml/h for all particle sizes. An iterative concentration process is performed to achieve a higher concentration factor for 10.2-mu m particles and Jurkat cells. With two stages of the concentration process, we were able to achieve over 98% recovery efficiency and a concentration factor of 10-11x. Cell viability was found to be above 96% after iterative concentration. We believe that this device could be used to concentrate cells as a preparatory step for studying low-abundance cells. Published by AIP Publishing.
Publisher
American Institute of Physics
ISSN
1932-1058
DOI
10.1063/1.5005612
URI
https://scholar.gist.ac.kr/handle/local/13605
공개 및 라이선스
  • 공개 구분공개
파일 목록
  • 관련 파일이 존재하지 않습니다.

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.