OAK

A Feasibility Study Comparing Body-Powered and Myoelectric Prostheses Using Plug-and-Play Module

Metadata Downloads
Author(s)
Adusumilli, Rishi; Poddar, Souvik; Sulaiman, Mohamed; Kang, Jiyeon
Type
Article
Citation
IEEE Access, v.14, pp.160801 - 160812
Issued Date
2026-10
Abstract
Two types of widely used prostheses are the body-powered prosthesis actuated with the shoulder/trunk movement and the myoelectric prosthesis actuated with a motor using sEMG signals. Even though these devices have been used for several decades, controlled quantitative comparisons that isolate the effects of prosthetic actuation strategy under identical mechanical interfaces remain limited. The challenges of the comparison studies stem from factors including different interfaces of these devices, different shape/length of the residual limb, the cause of amputation, or frequency of the prosthesis use during daily life. In this study, we designed a plug-and-play module that can change the body-powered prosthesis easily to a myoelectric prosthesis while keeping the interface structure of the body-powered prosthesis offering a cost-effective and personalized solution. Ten non-amputee participants were recruited to conduct three daily living tasks by wearing two different prostheses with a bypass of their own forearm. These participants were assumed to be novice users of both body-powered and myoelectric prostheses. The myoelectric prosthesis reduced compensatory ipsilateral elbow motion by approximately 30%, with significant reductions observed in two of the three tasks (p\lt 0.001), and contralateral shoulder motion by about 40%, with significant reductions observed across all three tasks (p\lt 0.01), compared to the body-powered prosthesis. Muscle activation in the biceps, triceps, and deltoids was substantially lower with the myoelectric prosthesis, showing reductions ranging from 50% to 60% (p\lt 0.001). Additionally, pressure exerted on the users back by the harness was drastically reduced due to the lack of straps in the myoelectric application (p\lt 0.001) when using the myoelectric prosthesis. © 2013 IEEE.
Publisher
Institute of Electrical and Electronics Engineers Inc.
ISSN
2169-3536
DOI
10.1109/ACCESS.2026.3744344
URI
https://scholar.gist.ac.kr/handle/local/34745
Appears in Collections:
Department of AI > 1. Journal Articles
공개 및 라이선스
  • 공개 구분공개
파일 목록
  • 관련 파일이 존재하지 않습니다.

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.