OAK

Analysis of Optimal integration of EVs and DGs into CIGRE's MV Benchmark Model

Metadata Downloads
Abstract
In today’s transportation sector, the growing number of electric vehicles (EVs) is progressively replacing petroleum-fueled vehicles, which are also expected to minimize greenhouse gas emissions. The main problem with EVs is the requirement of charging energy, which is fed through distribution network, while simultaneously feeding already connected load. The EV’s integration with the distribution network will overload the network due to EV’s charging load, which will eventually trip the power system protection. In this context, it is necessary to minimize power losses, improve voltage profile with sustainable power supply network. Therefore, optimal placement of EVs is required in the distribution network. Conventionally, researchers have used DGs to minimize power losses and improve voltage profile. In this paper, authors analyzed the effect of EV’s integration with simultaneous placement of distributed generations (DGs). The integration of EVs with higher penetration of DGs is cumbersome due to higher power losses and voltage variances that are outside allowable boundaries. The optimal placement of EVs into the distribution system with higher penetration of DGs is proposed in this paper using a battle royale optimization (BRO) algorithm. Since it is a new problem on CIGRE network which is not discussed before. Hence, the authors compared results with three most famous algorithms namely genetic algorithm (GA), particle swarm optimization (PSO), and accelerated PSO (APSO). The optimization problem is developed as a multi-objective function while decreasing active and reactive power losses, and minimising maximum voltage deviation index. The studied distribution network is the CIGRE 14-bus medium voltage (MV) distribution network. Three case studies are taken in which EVs are integrated in two scenarios with optimally sized and located DGs systems in the CIGRE distribution network using MATLAB. Case-1 includes simple network with DGs integration. Case-2 includes EVs only in the simple network, and case-3 finally includes EVs and DGs for optimal placement with minimum losses. The placement of the EVs results in a decrease in power losses and voltage deviation indices. The bus voltages of case-2, on the other hand, stay unchanged when the EVs are integrated. Case 3 with BRO showed the large reduction in power losses owing to the addition of EVs to the distribution network with DGs (from 19.98 kW, and 19.89 kVar to 2.54 kW, and 3.35 kVar).
Author(s)
Habib Ur Rahman HabibWaqar, AsadFarhan, Bashar SakeenAhmad, TanveerJahangiri, MehdiIsmail, Moustafa MagdiAhmad, ParvezAbbas, AsadKim, Yun-Su
Issued Date
2022-09
Type
Article
DOI
10.1109/ACCESS.2022.3204311
URI
https://scholar.gist.ac.kr/handle/local/10638
Publisher
Institute of Electrical and Electronics Engineers Inc.
Citation
IEEE Access, v.10, pp.1 - 1
ISSN
2169-3536
Appears in Collections:
Department of Electrical Engineering and Computer Science > 1. Journal Articles
공개 및 라이선스
  • 공개 구분공개
파일 목록
  • 관련 파일이 존재하지 않습니다.

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.