Abstract
The numerical study was conducted to compare process performance depending on the pump type and process configuration. The daily monitoring data of seawater temperature and salinity offshore from Daesan, Republic of Korea was used to reflect the site-specific seawater conditions. An algorithm for reverse osmosis in constant permeate mode was developed to simulate the process in time-variant conditions. Two types of pumps with different maximum leachable efficiencies were employed to organize pump-train configuration: separated feed lines and common pressure center design. The results showed pump type and design configuration did not have a significant effect on process performance. The annual means of specific energy consumption (SEC) for every design configuration were under 2 kWh/m(3), except for a worst-case. The worst-case was decided when the pump was operated out of the best operation range. The two operation strategies were evaluated to determine the optimal configuration. The permeate flow rate was reduced to 80% of the designed permeate flow rate with two approaches: feed flow rate reduction in every train and pump shutdown in a specific train. The operation mode with feed flow rate reduction was more efficient than the other. The operating pressure reduction led to a decrease in SEC.
Author(s)
Lim, Seung JiKi, Seo JinLim, Jae-LimLee, KyunghyukKim, JihyeMoon, JeongwooKim, Joon Ha
Issued Date
2022-11
Type
Article
DOI
10.3390/membranes12111145
URI
https://scholar.gist.ac.kr/handle/local/10517
Publisher
MDPI
Citation
MEMBRANES, v.12, no.11
ISSN
2077-0375
Appears in Collections:
Department of Environment and Energy Engineering > 1. Journal Articles
공개 및 라이선스
  • 공개 구분공개
파일 목록

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.