PtCo/C 촉매를 사용한 PEMFC MEA의 활성화 프로토콜 비교
- Alternative Title
- The Comparison of Activation Protocols for PEMFC MEA with PtCo/C Catalyst
- Abstract
- Three activation methods (constant voltage, current cycling, and hydrogen pumping) were applied to investigate the effects on the performance of the membrane electrode assembly (MEA) loaded with PtCo/C catalyst. The current cycling protocol took the shortest time to activate the MEA, while the performance after activation was the worst among the all activation methods. The constant voltage method took a moderate activation time and exhibited the best performance after activation. The hydrogen pumping protocol took the longest time to activate the MEA with moderate performance after activation. According to the distribution of relaxation time analysis, the improved performance after the activation mainly comes from the decrease of charge transfer resistance rather than the ionic resistance in the cathode catalyst layer, which suggests that the existence of water on the electrode is the key factor for activation.
- Author(s)
- 이기성; 정현승; 현진호; 박찬호
- Issued Date
- 2023-04